Having problems with your 2001 Ford Econoline ?

My air bearly blows out and I aready replaced the blower moter

Posted / edited by AnonymousUser on : 15-01-2018

Answers :

The duct work may be clogged or not attached properly in the dash somewhere
Repair Help & Product Troubleshooting for 2001 Ford Econoline

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

My air bearly blows out and I aready replaced the blower moter


The duct work may be clogged or not attached properly in the dash somewhere ... 2001 Ford Econoline

I have a Jimmy, the ac is charged, The heater blows hot. I know the moter that drives the air mix door is stripped. I can not install the replacement motor because the selector will not go to cold. Even when I hook up the new one it goes to hot. I can physicaly pinch off the heater hose and get the air to blow cold. have replaced the selector switches, the brain and need an idea on were to look next..how to get the thing to go to the cold setting so the new moter can be installed. C


Im not 100 % sure of what you are saying or what is actualy wrong but i do have the factory manual for this vehicle and the brake down is extensive as well as getting to some of these compounts is not easy . But if you want i will scan the pages and ... 1999 GMC Jimmy

I have a 2005 Sierra Diesel Duramax truck, I had to replace both batteries, everything was working just fine but now the AC/Heart blower is only blowing air out of the defrost vents, none of the dash vents have any air blowing out. Is there some kind of a reset I need to do or is there a safety feature that got engaged from replacing the batteries and how do I reset the blower?


... 2005 GMC Sierra

My 2004 Town and Country: I had a problem such that almost no air was blowing in front. I replaced the blower motor and the blower resistor with parts from Advanced Auto. Now I can't seem to select anything except air blowing through the vent--no floor or defrost. Also the rear is only blowing cold air. I would assume front a rear are separate systems and this is not related. Please advise. Does the resistor control the front and rear or just the front?


... 2004 Chrysler Town & Country

2002 Jeep Liberty - Air conditioner not blowing. Replaced blower relay switch - Still not blowing. When car is in motion, you can feel cold air at the vent, but the blower is not blowing the air into the car. Any ideas?


OK. So the blower notor isn't operating. Do you have power to the blower motor? The resistor is new from what I got. If you don't have power to the blower motor, then check the speed control switch and fuses. If you have power at the blower motor, re ... 2002 Jeep Liberty

2008 Nissan Rogue did not blow heat or Air. Mechanic checked the fuse, replaced blower motor, replaced resistor, replaced controls (all new parts). After paying $950.00 for parts and labor, vehicle blows air but its cold with the controls set at highest heat setting. Now must take car back again after a week in the shop. Do you know what the problem is so I can tell him what to look at.


... Cars & Trucks

2007 Ford Ranger XLT - blower motor resister replaced; blower motor replaced; actuator door replaced;... and air conditioner still not blowing cold air. And dash temp guage remains on cool


... Ford Ranger

Ok, may sound like a dumb question,but how do you know if its a blower motor resistor problem or just the blower/motor. Ive been reading solutions for problem on the A/C blower still blowing air but speeds off or that the blower works sometimes and sometimes not. If my A/C doesnt blow air at all, do I just replace the motor or resistor? --Sonia


The blower motor resistor is usually only switched into the circuit for the lower speeds and for the fastest speed the resistor is bypassed so I guess the motor needs to be replaced if it does not work in any position. However, sometimes the blower m ... 2006 Nissan Altima

Sentra AC For a little while now my '94 Nissan Sentra has only blown cold air on the highest blower speed (the fourth position). The other three positions still blew air, it was just lukewarm. Recently, though, the fourth speed stopped blowing altogether. To recap: positions 1-3 blow but not cold, and position 4 doesn't blow at all. I replaced the blower resistor and everything is still acting the exact same way. Any ideas?


There's a 10amp fuse that powers the ac clutch relay and compressor. There are 15amp fuses that power the blower motor and the ac control switch. All of those fuses get power from the key switch. The resistor and fan switch provide the ground circ ... Cars & Trucks

Air blower I replaced my blower motor that was making a noise but blowing air on all 3 speeds. The new one runs but will not harley blow any air.


Wires to blower may be crossed or blower resister is bad. ... 1994 GMC Sierra

Heater I have a 2000 Jeep Grand Cherokee Limited. V8. The car has had all the typical jeep issues I have replaced the tail lamps and the entire air conditioning system. Just recently when I turn on the heat it blows cool air. The blower is fine as it blows according to the setting. However, I turn the temperature dials to HI and still blows cool air. When I turn to defrost the air gets barely warm, not warm enough to melt an ice cube. What could be the issue?


Your blend doors are broken a common problem for the jeeps 1999-2004 e mail me at [email protected] and i will send you a link to a web site for a repair kit that will cost les than the ... 2000 Jeep Grand Cherokee

Greetings this is my first post here. I have a heating problem with my 2001product dodge grand caravan sport . The heater blows cold air but as i drive it will blow hot air briefly then back to cold air. I just replaced my blower motor resistor hoping for the best and it still blows cold air. My coolant res is emty but my radiator is topped no leaks and im not overheating please help me someone its cold here in NY


Glad you found the problem ... Cars & Trucks

F150 1997 v8 , blower vent will only blow out the windshield not ant of the vents. also it will only blow cold air. i replaced the switch that controls the flow direction of the air. but still same problem. also removed the dash and opened the blower box and the door was closed adn wouldn't move.


Check the stepping motor that move the doors, it is the little white box at the bottom of the environmental station it opens and closes the door, when you remove it you can hook it up to the harness and operate the temp control see if the motor turns ... 1997 Ford F150 Regular Cab

2000 Chevy Tahoe 5.3 V8. The front blower will only blow warm air while the rear blower will blow hot air. The vehicle also takes a long time to warm up. I have replaced the thermostat and coolant. Even after the fix, it continues to display the problem.


... 2000 Chevrolet Tahoe

Heater blows cold air ,at idle and blower motor off,if you wait a couple of min and turn on blower it will blow warm air for a few mins then back to luke warm. i replaced thermostat did not help


The heater control valve is not opening all the way.\015\012look under the hood on one on the heater hoses .\015\012you should find a vaccum controled heater hose valve.\015\012make sure your not low on coolant also.\015\012al ... 2000 Chrysler Sebring

Well first the front air conditioner quit blowing all together... thought it was the blower motor ordered it didn't drive it for a week went replace the motor and it was blowing just not cold... but the rear air was working fine... now neither will blow cold.. and I checked the freon pressure with the front apron and the clutch would cycle on n off the stay on and the pressure would read 15 to 20... between I turn that off and check Tue rear air it doesn't read anything...


Your best bet would be to go in and get an estimate from a shop for the fix. You can never go wrong with just getting an experts opinion, and they will usually be "dumb"/ nice enough to tell you what you need to fix it. However knowing this it is mor ... Dodge Durango

I replaced the blower motor and the air is not blowing out the dash vents. the air only blows from the foot vents and the air doesn't blow at all on the high setting.


This sounds like it could be 1 or 2 different problems. The first is the control head. Obviously if the control head is malfunctioning it is not sending the proper signals to the the blend door. If the control head is ok, then it could be the blend d ... 1995 Chevrolet Lumina Apv

My air condition blower wont' blow air except on low. Sometimes it will start blowing hi on its own. Comes and goes. Replaced the air control console, and it worked for a while then started do


Might have drunken. Wait for some time and re-try. ... Toyota Avalon

Blower Motor fuses keep on blowing. During summer seasons the air has blown from my car with a loud rattling noise until it went kaput and nothing blows at all. I replaced the fuses under the hood labeled "Blower Motor" only to find that the fuse keeps on blowing once I turn on the HVAC So, why do they keep blowing? And how do I fix it? Perhaps I should fix that rattling noise problem first? Technical terms appreciated.


I believe the ultimate problem is with the blower motor itself.They can get water in them, dirt and general grot. The motor will be on the passenger side up under the dash and will be held in with three screws.You are going to have to remove the moto ... 2002 Nissan Maxima

I have a 1995 Lexus LS400 and the heater/AC won't work. I replaced the heater blower relay along with the blower motor control realy and it still doen't blow air from the vents. My friend is a


... Cars & Trucks

1998 Oldsmobile Cutlass-My blower will not blow hot or cold air. Hot and cold air will come out of the vents but it's not being blown out of the vents. The blower itself works fine when hooked directly to the car battery. Voltage is good at the connector to the blower and I replaced the resistor. Problem is still unresolved.


You got a bad ground wire on your blower motor hook a seprate ground to it then ground to the chasis ... 1998 Oldsmobile Cutlass

Air vents No air comes thru vent,Blower moter works fine. I've tried on every position on switch,Replaced entire switck,Pulled and checked blower moter.Still no air thru vents


THE DEFROSTER DOOR WAS FROZEN SHUT. WHICH CAUSED COMPUTER SWITCH TO GO OUT.HAD TO REPLACE THE DEFROSTER BOX(?) AND COMPUTER SWITCH. WORKS FINE NOW. ... 2000 Chevrolet Lumina

Hello my repair problem on 89 lincoln town car is what... I HAVE REPLACED THE HEATER CONTROL VALVE, TEMPERATURE GAUGE, THERMOSTAT, REPLACED WITH STRAIGHT ANTIFREEZE, AND NO LINK FROM HEATERCORE AND THE AREA NEAR HEATERCORE IS WARM AND THE BLOWER BLOWS HEAT WHEN FIRST TURN ON CAR AND CONTINUE TO BLOW OUT COOL AIR AND ALSO REMOVED THE ELECTRICAL WIRE ON THE COMPRESSOR TO A/C TO SEE WHETHER THE IT WOULD BLOW HEAT STILL NO GO AND IT NOT RUNNING HOT NOW HOW CAN I RECIEVE HEAT ALSO CHECKED ALL VACCUMS


Never use straight antifreeze water is needed to give it its cooling properties at most the ratio should be 60/40 antifreeze / water. It sounds like a bad check valve locate and replace. ... 1989 Lincoln Town Car

My 1993 toyota camry air blower will not blow air through the vent on the setting that blows at your face. all the other settings will let air through them but this setting will not. what is wrong and do i need to replace a acuator somewhere and if so where is it located and how to i access it?


You will need to replace the blend door actuator, it is located \015\012in the air box near the blower motor. Before you replace that, check your cable that controls the opening and closing of the door because it may just need an adjustment. ... Toyota Camry

Fuse#28 (5A, air-conditioner, blower, heater) keeps blowing on my 2001 BMW 325i. It kills the whole A/C, heater, blower console. I replaced my fuse twice but it's blown again after a few days. These problems began a few days after i replaced my coolant overflow tank which had a crack in it. I have already replaced my final stage resistor 2 years back. Any suggestions on where i should look??


Maybe you have caused a short somewhere when replacing the overflow bottle... what i would do is run a 5 amp higher fuse NO MORE THEN 5 and if this blows then you have a bigger problem ... 2001 BMW 325