Hi
\015\012
\015\012The heat is controlled by the vacuum motors under the dash each time you make a change in your HVAC a separate vacuum motor will open or close a different heater door. If the defroster and the floor work this tells us there is vacuum at the control switch, so knowing this it is safe to assume there is a problem with the HVAC motor that is for the vent position, most likely under the dash where you will find several silver vacuum motors each will have one or two vacuum hoses ---- one is not hooked upright have a bad vacuum motor for one of the doors for the ducts.
\015\012It can also be that you have a Vacuum leak at the Vacuum Canister or a bad Vacuum hose. The hoses are very small (about 1/8 or 3/16 inch) some- times it’s a Actuator 4 the mixer doors but mostly its just a small Vacuum leak. Check the hoses from the intake manifold to the fire—wall as they could have gone bad.
\015\012
\015\012Please do accept the solution if the issue is resolved or else revert for further assistance.
\015\012
\015\012
\015\012Thanks
\015\012Rylee
Repair Help & Product Troubleshooting for 1998 Buick LeSabre

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

Loading ...

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || www.carrestorationshop.com || Terms of Use || Contact || Privacy Policy
Load time: 0.0126 seconds